Catheterization, Swan-Ganz
"Catheterization, Swan-Ganz" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Placement of a balloon-tipped catheter into the pulmonary artery through the antecubital, subclavian, and sometimes the femoral vein. It is used to measure pulmonary artery pressure and pulmonary artery wedge pressure which reflects left atrial pressure and left ventricular end-diastolic pressure. The catheter is threaded into the right atrium, the balloon is inflated and the catheter follows the blood flow through the tricuspid valve into the right ventricle and out into the pulmonary artery.
Descriptor ID |
D002407
|
MeSH Number(s) |
E01.370.370.380.140.210 E02.148.224.165 E02.148.442.165 E04.100.814.529.937.165 E04.502.382.937.165 E05.157.250.165 E05.157.375.165
|
Concept/Terms |
Pulmonary Artery Catheterization- Pulmonary Artery Catheterization
- Artery Catheterization, Pulmonary
- Artery Catheterizations, Pulmonary
- Catheterizations, Pulmonary Artery
- Pulmonary Artery Catheterizations
- Catheterization, Pulmonary Artery
|
Below are MeSH descriptors whose meaning is more general than "Catheterization, Swan-Ganz".
- Analytical, Diagnostic and Therapeutic Techniques and Equipment [E]
- Diagnosis [E01]
- Diagnostic Techniques and Procedures [E01.370]
- Diagnostic Techniques, Cardiovascular [E01.370.370]
- Heart Function Tests [E01.370.370.380]
- Cardiac Catheterization [E01.370.370.380.140]
- Catheterization, Swan-Ganz [E01.370.370.380.140.210]
- Therapeutics [E02]
- Catheterization [E02.148]
- Catheterization, Peripheral [E02.148.224]
- Catheterization, Swan-Ganz [E02.148.224.165]
- Cardiac Catheterization [E02.148.442]
- Catheterization, Swan-Ganz [E02.148.442.165]
- Surgical Procedures, Operative [E04]
- Cardiovascular Surgical Procedures [E04.100]
- Vascular Surgical Procedures [E04.100.814]
- Endovascular Procedures [E04.100.814.529]
- Catheterization, Peripheral [E04.100.814.529.937]
- Catheterization, Swan-Ganz [E04.100.814.529.937.165]
- Minimally Invasive Surgical Procedures [E04.502]
- Endovascular Procedures [E04.502.382]
- Catheterization, Peripheral [E04.502.382.937]
- Catheterization, Swan-Ganz [E04.502.382.937.165]
- Investigative Techniques [E05]
- Catheterization [E05.157]
- Cardiac Catheterization [E05.157.250]
- Catheterization, Swan-Ganz [E05.157.250.165]
- Catheterization, Peripheral [E05.157.375]
- Catheterization, Swan-Ganz [E05.157.375.165]
Below are MeSH descriptors whose meaning is more specific than "Catheterization, Swan-Ganz".
This graph shows the total number of publications written about "Catheterization, Swan-Ganz" by people in this website by year, and whether "Catheterization, Swan-Ganz" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
1994 | 1 | 0 | 1 |
To return to the timeline,
click here.
Below are the most recent publications written about "Catheterization, Swan-Ganz" by people in Profiles.
-
Jenders RA, Estey G, Martin M, Hamilton G, Ford-Carleton P, Thompson BT, Oliver DE, Eccles R, Barnett GO, Zielstorff RD, et al. Indexing guidelines: applications in use of pulmonary artery catheters and pressure ulcer prevention. Proc Annu Symp Comput Appl Med Care. 1994; 802-6.
-
Earp JK, Finlayson DC. Urinary bladder/pulmonary artery temperature ratio of less than 1 and shivering in cardiac surgical patients. Am J Crit Care. 1992 Sep; 1(2):43-52.