John Tarbell to Hemolysis
This is a "connection" page, showing publications John Tarbell has written about Hemolysis.
Connection Strength
0.458
-
Garrison LA, Frangos JA, Geselowitz DB, Lamson TC, Tarbell JM. A new mock circulatory loop and its application to the study of chemical additive and aortic pressure effects on hemolysis in the Penn State electric ventricular assist device. Artif Organs. 1994 May; 18(5):397-407.
Score: 0.107
-
Lamson TC, Stinebring DR, Deutsch S, Rosenberg G, Tarbell JM. Real-time in vitro observation of cavitation in a prosthetic heart valve. ASAIO Trans. 1991 Jul-Sep; 37(3):M351-3.
Score: 0.088
-
Baldwin JT, Deutsch S, Geselowitz DB, Tarbell JM. Estimation of Reynolds stresses within the Penn State left ventricular assist device. ASAIO Trans. 1990 Jul-Sep; 36(3):M274-8.
Score: 0.082
-
Kini V, Bachmann C, Fontaine A, Deutsch S, Tarbell JM. Flow visualization in mechanical heart valves: occluder rebound and cavitation potential. Ann Biomed Eng. 2000 Apr; 28(4):431-41.
Score: 0.041
-
Maymir JC, Deutsch S, Meyer RS, Geselowitz DB, Tarbell JM. Mean velocity and Reynolds stress measurements in the regurgitant jets of tilting disk heart valves in an artificial heart environment. Ann Biomed Eng. 1998 Jan-Feb; 26(1):146-56.
Score: 0.035
-
Maymir JC, Deutsch S, Meyer RS, Geselowitz DB, Tarbell JM. Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve. Artif Organs. 1997 Sep; 21(9):1014-25.
Score: 0.034
-
Garrison LA, Lamson TC, Deutsch S, Geselowitz DB, Gaumond RP, Tarbell JM. An in-vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis. 1994 Apr; 3 Suppl 1:S8-22; discussion S22-4.
Score: 0.027
-
Lamson TC, Rosenberg G, Geselowitz DB, Deutsch S, Stinebring DR, Frangos JA, Tarbell JM. Relative blood damage in the three phases of a prosthetic heart valve flow cycle. ASAIO J. 1993 Jul-Sep; 39(3):M626-33.
Score: 0.025
-
Zapanta CM, Stinebring DR, Sneckenberger DS, Deutsch S, Geselowitz DB, Tarbell JM, Synder AJ, Rosenberg G, Weiss WJ, Pae WE, Pierce WS. In vivo observation of cavitation on prosthetic heart valves. ASAIO J. 1996 Sep-Oct; 42(5):M550-5.
Score: 0.008
-
Baldwin JT, Tarbell JM, Deutsch S, Geselowitz DB. Mean velocities and Reynolds stresses within regurgitant jets produced by tilting disc valves. ASAIO Trans. 1991 Jul-Sep; 37(3):M348-9.
Score: 0.006
-
Jarvis P, Tarbell JM, Frangos JA. An in vitro evaluation of an artificial heart. ASAIO Trans. 1991 Jan-Mar; 37(1):27-32.
Score: 0.005